Millenium Plus 70 Door System with Thermal Break

Millenium Plus 70 Door System with Thermal Break

Coplanar door entry system with straight 70mm and thermally broken for commercial premises and buildings. With a frame transmission value from 0.9 W/m² K, it reaches unbeatable thermal features and its great glazing capacity guarantees a máximum accoustic insulation.

Possibility of high resistance hinges (face fix or re-inforced in to the channel) capable of supporting up to 220kgs in weight per sash.
Possibility of hidden hinges with máximum dimensions and weight per sash of 2700mm in height, 1500mm in width and 120kgs. and with a máximum sash opening of 100°.
It presents solutions of finishing to the floor and compatible meeting styles with our actual systems.

It is valid as a configuration for an emergency exit with anti-panic devices according to EN 179 & EN 1125 norms.
There is the possibility to integrate a motorization automation to allow automatic hinged openings.

TECHNICAL DATA :

Accoustic insulation

Maximum glazing: 54 mm

Maximum accoustic insulation: Rw = 38 dB

Transmittance

Uw from 0,9 (W/m²K)

Please consult typology, dimensions and glass

Compliance Zones of RCCTE* I1 I2 I3
*Depending on the transmission coefficient thermal glass

Opening possibilities

Open In: Practicable 1 & 2 sashes

Open Out: Practicable1 & 2 sashes

Automatic Opening: Internal & external hinged single sash

   

Sections / Profile thickness

Sections:
· Frame – 70 mm
· Sash – 70 mm

Profile thickness:
· Door – 2,0 mm

Polyamide strip width: 24 mm

Maximum dimensions / Maximum weight

Maximum dimensions:
Width (L) = 1.800 mm
Height (H) = 3.000 mm

Maximum weight/sash: 220 Kg

Maximum weight/sash (hidden hinges): 120 Kg

Please consult regarding maximum weight and dimensions for other opening types

Categories achieved at test centre

Air permeability (EN 12207:2000): Class 4

Water tightness (EN 12208:2000): Class 6A

Wind resistance (EN 12210:2000): Class C4

Door test reference: 1,20 m x 2,30 m. 1 sash.

Resistance to mild impact (EN 13049:2003): Class 5 (max)

Test on door reference: 1,80 x 2,20 m. 2 sashes. Laminated glass 3 + 3.

Resistance to repeated openings and closings (EN 1191:2000): 1.000.000 cycles

Test on door reference: 2.10 mx 2,20 m. 2 sashes.

Finishes

· Possibility of dual colour

· Colour powder coating (RAL, mottled & rough)

· Wood effect powder coating

· Anti-bacterial powder coating

· Anodized

Millenium FR Door System with Thermal Break

Este nuevo sistema de puerta cortafuegos de aluminio con clasificación de resistencia al fuego clase EI60